🔍 CVE-2022-30315

9.8
CVSS Score
CRITICAL
2022-07-28
2026-06-17 04:43
✅ 완료

🇰🇷 한글 설명

Honeywell Experion PKS Safety Manager의 Safety Builder 프로토콜에서 데이터 인증 검증이 미흡하여 발생하는 취약점입니다. 공격자가 인증되지 않은 제어 로직을 다운로드함으로써 컨트롤러의 CPU 모듈에서 임의의 기계 코드를 실행하거나 서비스 거부(DoS)를 유발할 수 있습니다.

💡 쉬운 설명

안전 장치를 관리하는 시스템이 전달받은 명령이 진짜인지 확인하지 않는 결함이 있습니다. 해커가 가짜 명령을 보내 시스템을 멈추게 하거나 마음대로 조종할 수 있는 위험한 상태입니다.

🇺🇸 원문 (English)

Honeywell Experion PKS Safety Manager (SM and FSC) through 2022-05-06 has Insufficient Verification of Data Authenticity. According to FSCT-2022-0053, there is a Honeywell Experion PKS Safety Manager insufficient logic security controls issue. The affected components are characterized as: Honeywell FSC runtime (FSC-CPU, QPP), Honeywell Safety Builder. The potential impact is: Remote Code Execution, Denial of Service. The Honeywell Experion PKS Safety Manager family of safety controllers utilize the unauthenticated Safety Builder protocol (FSCT-2022-0051) for engineering purposes, including downloading projects and control logic to the controller. Control logic is downloaded to the controller on a block-by-block basis. The logic that is downloaded consists of FLD code compiled to native machine code for the CPU module (which applies to both the Safety Manager and FSC families). Since this logic does not seem to be cryptographically authenticated, it allows an attacker capable of triggering a logic download to execute arbitrary machine code on the controller's CPU module in the context of the runtime. While the researchers could not verify this in detail, the researchers believe that the microprocessor underpinning the FSC and Safety Manager CPU modules is incapable of offering memory protection or privilege separation capabilities which would give an attacker full control of the CPU module. There is no authentication on control logic downloaded to the controller. Memory protection and privilege separation capabilities for the runtime are possibly lacking. The researchers confirmed the issues in question on Safety Manager R145.1 and R152.2 but suspect the issue affects all FSC and SM controllers and associated Safety Builder versions regardless of software or firmware revision. An attacker who can communicate with a Safety Manager controller via the Safety Builder protocol can execute arbitrary code without restrictions on the CPU module, allowing for covert manipulation of control operations and implanting capabilities similar to the TRITON malware (MITRE ATT&CK software ID S1009). A mitigating factor with regards to some, but not all, of the above functionality is that these require the Safety Manager physical keyswitch to be in the right position.

📍 영향받는 시스템

Honeywell Experion PKS Safety Manager (FSC-CPU, QPP), Honeywell Safety Builder (R145.1, R152.2 포함 전 버전 의심)

⚔️ 공격 벡터

Safety Builder 프로토콜을 통해 인증되지 않은 제어 로직(FLD 코드)을 컨트롤러로 다운로드하여 공격

🛡️ 대응 방법

Honeywell의 보안 권고에 따라 최신 패치를 적용하고, 물리적 키스위치 위치를 확인하며 네트워크 접근 제어를 강화하십시오.

🔧 검증 코드

해당 취약점은 소프트웨어 버전 확인만으로는 부족하며, Honeywell 전용 진단 도구를 통해 프로토콜 보안 설정 및 펌웨어 무결성을 점검해야 합니다.

Shell / Script
echo 'Honeywell Experion PKS Safety Manager version check required via vendor tool'

📊 CVSS Vector String

CVSS Vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H

💻 영향받는 소프트웨어

Spring Data REST