🔍 CVE-2026-102511

0.0
CVSS Score
UNKNOWN
2026-09-30
2026-09-30 17:16
✅ 완료

🇰🇷 한글 설명

Apache PLC4X의 Go 구현체(PLC4Go) 및 PLC4J의 ADS, Modbus, EtherNet/IP 드라이버에서 통신 채널 소스 검증 미흡 취약점이 발견되었습니다. 공격자가 조작된 UDP 데이터그램을 전송하면 연결 주소를 임의의 주소로 리다이렉트하거나, 서비스 거부(DoS)를 유발하여 디스커버리 리스너를 중단시킬 수 있습니다.

💡 쉬운 설명

네트워크 장치를 찾는 과정에서 가짜 정보를 보내 사용자의 연결을 해커의 컴퓨터로 유도하거나, 장치 찾기 기능을 마비시킬 수 있는 보안 약점입니다. 이를 통해 중요한 데이터가 잘못된 곳으로 전송될 위험이 있습니다.

🇺🇸 원문 (English)

Improper Verification of Source of a Communication Channel in the ADS discovery of the Go implementation of Apache PLC4X (PLC4Go) allows an attacker able to send UDP datagrams to the discovering host to redirect subsequent connections to an arbitrary, attacker-chosen address. The discovery result's connection address was derived from the AmsNetId claimed in the response body rather than from the datagram's actual source address. One spoofed discovery response can therefore insert an inventory entry pointing at any host, including hosts outside the local network, and an application that connects to discovered devices will open its ADS session, including any configured route credentials, to that host. Additionally, discovery listeners in both implementations can be disabled by a single malformed datagram: - In PLC4Go ADS discovery, a short version block causes a panic that ends the listener for the rest of the discovery call, so legitimate devices answering afterwards are not reported. - In PLC4J, the ADS and EtherNet/IP discoverers stop on an unhandled exception from a malformed response. - The PLC4J Modbus discoverer can be made to spin indefinitely, consuming a CPU core, by a scanned host that sends a partial response. Exploitation requires the application to invoke the discovery API, which is opt-in, and for the connection redirect, to act on the discovered items. This issue affects Apache PLC4X: PLC4Go from 0.11.0 before 1.0.0; PLC4J ADS and Modbus drivers from 0.10.0 before 1.0.0; PLC4J EtherNet/IP driver from 0.11.0 before 1.0.0. PLC4Go is consumed as the Go module github.com/apache/plc4x/plc4go; versions refer to the corresponding Apache PLC4X releases. Users are recommended to upgrade to version 1.0.0, which fixes the issue. Version 1.0.0 derives the connection address from the datagram's source address and logs a warning when the claimed AmsNetId disagrees with it.

📍 영향받는 시스템

PLC4Go 0.11.0~1.0.0 미만, PLC4J ADS/Modbus 0.10.0~1.0.0 미만, PLC4J EtherNet/IP 0.11.0~1.0.0 미만

⚔️ 공격 벡터

UDP 데이터그램을 이용한 조작된 ADS 디스커버리 응답 전송

🛡️ 대응 방법

Apache PLC4X 버전을 1.0.0 이상으로 업그레이드

🔧 검증 코드

출력된 모듈 버전이 1.0.0 미만인지 확인하여 취약 여부를 판단합니다.

Shell / Script
go list -m github.com/apache/plc4x/plc4go || echo 'Not found'